Asset Model Update - November 2024
Asset Models for the following Industrial Control Systems (ICS) have been released. For a complete list of enhancement/fixes, please refer to the product Release Notes.
For more information about these asset models, create a support ticket through the Smart Community Portal.
Asset Models Released and/or Updated:
Honeywell PHD v5.22.0.0
Enhancements/Fixes Include:
- Fixed an import error when parsing TagValueType objects and building asset tree hierarchy.
- Added external references to Siemens PCS7 assets.
- New Data Collection is NOT REQUIRED when upgrading to this new version of the asset model from previous version.
Schweitzer SEL Blueframe v1.0.0.7
Enhancements/Fixes Include:
- This is a NEW asset model used to collect and import configuration and Inventory information of Schweitzer Relays and RTAC devices from SEL Blueframe application.
- The data collection script allows the export of configuration and inventory information for all Schweitzer Relays and RTAC devices configured within an SEL Blueframe application instance, consolidating them into a single collection.
- This asset model also collects and displays password age for the SEL Blueframe application users/levels.
- PAS Inventory Items Asset Model will be updated to add a sequence to create inventory items from Schweitzer SEL Blueframe Asset Model.
PAS Inventory Items v3.0.0.7
Enhancements/Fixes Include:
- New Inventory Sequence created for Woodward GAP.
- New Inventory sequence created for Schweitzer SEL Blueframe.
- Fixed issue with PAS Inventory Items version 1.14 missing fields for Siemens S7400 inventory.
- Resolved issue of VM showing zero risk for endpoint of Siemens S7 400.
- Siemens S7 400, AB ControlLogix, TS1131, and Schneider Foxboro Evo updated to fetch inventory information from base asset model if not available in ACCDB.
- Updated the AB SLC500 Inventory to fetch the details from the Inventory ACCDB file.
- Updated the Siemens PCS7 Inventory to fetch the details from the inventory ACCDB file.
- Resolved import error for Invensys Infusion inventory.
- Updated Siemens PCS7 Inventory to get IP address from PCS7 objects.
- Triconex TS1131 Inventory is now created from Slot objects from base model.
- RUSLS module added in Honeywell SM Inventory.
- "V" removed from Version Number property value of Siemens S7 400 Hardware inventory.
- ABB Freelance Inventory - Added support for additional hardware. Also updated to fetch the details from the inventory ACCDB file.
- AB ControlLogix Inventory - Asset model updated to create missing inventory items.
- HIMA Elop II inventory - Added IP Address and ParentID for Inventory Items. Controller Inventory is created from Module ObjectType. CU Module object is made Cyber Asset.
- Emerson Ovation Inventory - Fixed endpoint Hierarchy and location issue. Ouids are updated with new naming convention.
- Updated Siemens T3000 Inventory to fetch correct firmware version.
- Updated Recon Inventory to fetch Product and Model Number from object Ouid.
- Updated Recon Inventory to resolve import error.
Rockwell Studio 5000 v2.0.0.0
Enhancements/Fixes Include:
- Optimization of Asset Model for inventory-only import purposes.
- Added Asset property Inventory Only Import in the asset model that allows the import of inventory-only information.
- Fixed an import error.
- Fixed an issue with AB CLX tags not showing referential relationship maps with Honeywell EPKS.
- New Data Collection is NOT REQUIRED when upgrading to this new version of the asset model from previous version.
- PAS Inventory Items asset model WILL NOT BE UPDATED based on the changes in this model release.